LG 6CIM0-01B Engineering Product Data Book

Download or browse on-line these Engineering Product Data Book for LG 6CIM0-01B Air Conditioner.

LG 6CIM0-01B Manual Information:

This manual for LG 6CIM0-01B, given in the PDF format, is available for free online viewing and download without logging on. The guide contains 94 pages, and the size of the file at download is . The document type is Engineering Product Data Book.

Download Manual

This sample of LG 6CIM0-01B Manual is aimed at the following devices list: AMNW09GB1A0, AMNW09GDBL0, AMNW18GB2A0, AMNW18GDCL0, 6CIM0-01B

Summary of Contents:

[Page 1] LG 6CIM0-01B

Indoor unit R410A 6CIM0-01B (Replaces 6CIM0-01A) ...

[Page 2] LG 6CIM0-01B

Introduction Preface New era brings the more sophisticated and advanced buildings which in turn demands for specialized and optimized direct expansion air conditioning systems. Also energy efficiency, low noise and low maintenance are the features w...

[Page 3] LG 6CIM0-01B

General information 1. Model line up 2. Nomenclature 3. Appearance Indoor unit ...

[Page 4] LG 6CIM0-01B

Heat pump 60Hz/R410A _ 1 General information Indoor unit 1. Model line up 2.64 (9) 5.28 (18) 3.52 (12) ARTCOOL Mirror Category Model names Capacity, kW(kBtu/h Class) Chassis Wall mounted Ceiling cassette SB SC SB SC TR TQ AMNW09GDBL0 [LMN096HVT] AM...

[Page 5] LG 6CIM0-01B

2 _ Heat pump 60Hz/R410A General information Indoor unit 2.1 Global model names AMN W G 09 BDL0 Serial number Indicates that this is multi system indoor unit using R410A Model type W : DC Inverter heat pump Ex) 9,000 Btu/h Class → '09&apos...

[Page 6] LG 6CIM0-01B

Heat pump 60Hz/R410A _ 3 General information Indoor unit 3. Appearance 3.1 Indoor units • ART COOL Mirror • Ceiling Cassette 4-way• Ceiling Concealed Duct – Low static pressure AMNW09GB1A0 [LMDN095HV] AMNW12GB1A0 [LMDN125HV] AMNW18GB2A0 [LM...

[Page 7] LG 6CIM0-01B

1. Wall Mounted 2. ART COOL Mirror 3. Ceiling cassette 4-way 4. Ceiling concealed duct - Low static pressure Indoor unit ...

[Page 8] LG 6CIM0-01B

Wall Mounted 1. List of functions 2. Specifications 3. Dimensions 4. Piping diagrams 5. Wiring Diagrams 6. Capacity Tables 7. Air flow and temperature distributions (reference data) 8. Sound levels 9. Controller 10. Installation Indoor unit ...

[Page 9] LG 6CIM0-01B

1. List of functions Note : 1. * : These functions need to connect the wired remote controller. O : Applied, X : Not applied Accessory model name : Installed at field, ordered and purchased separately by the corresponding model name, supplied with...

[Page 10] LG 6CIM0-01B

Note : 1. Wiring cable size must comply with the applicable local and national code. 2. Due to our policy of innovation some specifications may be changed without notification. 3. Sound Level Values are measured at Anechoic chamber. Therefore, these ...

[Page 11] LG 6CIM0-01B

Wall mounted _ 3 3. Dimensions Indoor Units Indoor unit 1. Unit should be installed in compliance with the installation manual in the product box. 2. Unit shall be grounded in accordance with the local regulations or applicable national co...

[Page 12] LG 6CIM0-01B

3. Dimensions 1. Unit should be installed in compliance with the installation manual in the product box. 2. Unit shall be grounded in accordance with the local regulations or applicable national codes. 3. The Unit is powered from the outdo...

[Page 13] LG 6CIM0-01B

Gas pipe connection port (flare connection) Liquid pipe connection port (flare connection) Cooling Heating Thermistor for Evaporator middle temperature Thermistor for Evaporator Inlet Temperature Thermistor for Indoor Air Temperature Thermistor...

[Page 14] LG 6CIM0-01B

5. Wiring diagrams Models : AMNW09GDBL0 [LMN096HVT] / AMNW12GDBL0 [LMN126HVT] Models : AMNW18GDCL0 [LMN186HVT] 6 _ Wall mounted Indoor Units Indoor unit ...

[Page 15] LG 6CIM0-01B

n Cooling Capacity Notes: 1. Capacities are based on the following conditions. Corresponding refrigerant piping length : 25ft Level difference : 0ft 2. TC : Total Capacity(kBtu/h) SHC: Sensible Heat Capacity(kBtu/h) Cooling Capacity Unit Size (kBtu...

[Page 16] LG 6CIM0-01B

Notes: 1. Capacities are based on the following conditions. Corresponding refrigerant piping length : 25ft Level difference : 0ft 2. TC : Total Capacity(kBtu/h) Unit Size (kBtu/h(kW)) Indoor air temp. °F DB Outdoor Air Temp. °F WB 5 1423324350 59 ...

[Page 17] LG 6CIM0-01B

7. Air flow and temperature distributions (reference data) Model : AMNW12GDBL0 [LMN126HVT] Cooling Heating 72 68 75 64 Air velocity [ft/s] Temperature [°F] 3.3 6.6 4.9 1.6 9ft 7ft 3ft 0ft 16ft 13ft 10ft 7ft 3ft 0ft 9ft 7ft 3ft 0ft 16ft 13ft 10ft 7f...

[Page 18] LG 6CIM0-01B

Model : AMNW18GDCL0 [LMN186HVT] Cooling Heating 3.3 6.6 4.9 1.6 Temperature [°F] 91 86 81 75 70 Air velocity [ft/s] 9ft 7ft 3ft 0ft 26ft 23ft 20ft 16ft 13ft 10ft 7ft 3ft 0ft 9ft 7ft 3ft 0ft 26ft 23ft 20ft 16ft 13ft 10ft 7ft 3ft 0ft 64 68 72 75 3.3...

[Page 19] LG 6CIM0-01B

8. Sound levels Overall 2.6ft 3.3ft Microphone Notes: - Sound measured at 3.3ft away from the center of the unit. - Data is valid at free field condition. - Data is valid at nominal operation condition. - Reference accoustic pressure 0dB=20µPa. - S...

[Page 20] LG 6CIM0-01B

9. Controller Wireless remote control Display screen Control panel * Some functions may not be supported, depending on the model. Control panel Display screen Description a F Plasma button*:Plasmaster filter purifies the air by removing mites, mi...

[Page 21] LG 6CIM0-01B

10. Installation Name Diagram Installation panel SB Chassis SC Chassis Securing screws Type "A" screw Type "B" screw M4 x 12L (Other) • Owner's manual • Installation manual 10.1 Accessories The following accessories are...

[Page 22] LG 6CIM0-01B

Type 1: SB Chassis 133(5 1/4) 95(3 3/4) Installation plate Left rear piping Right rear piping Ø70(Ø2 3/4) Ø70(Ø2 3/4) Unit : mm(inch) 2) Installation plate dimensions 14 _ Wall mounted 10. Installation Indoor Units Indoor unit ...

[Page 23] LG 6CIM0-01B

Type 2: SC Chassis Ø70(Ø2-3/4) Ø70(Ø2-3/4) 69(2 23/32) 56(2 7/32) Right rear piping Left rear piping Installation Plate Measuring Tape Measuring Tape Hanger Place a level on raised tab Unit Outline 207(8 5/32) 105(4 1/8) Unit : mm(inch) 460(18 ...

[Page 24] LG 6CIM0-01B

10.2 Selection of the best location ① There should not be any heat or steam near the unit. ② Select a place where there are no obstacles around of the unit. ③ Make sure that condensation drainage can be conve- niently routed away. ④ Do not in...

[Page 25] LG 6CIM0-01B

Wrong method • Following bending type from left to right may cause dam- age to the tubing. 10.5 Connecting the piping ① Pull the screw cap at the bottom of the indoor unit ② Remove the chassis cover from the unit by loosing 2 screws ③ Pull ba...

[Page 26] LG 6CIM0-01B

Wiring and Piping Connection ① Insert the connecting cable through the bottom side of indoor unit and connect the cable (You can see detail contents in 'Connecting the cables' section) ② Secure the cable onto the control board with the ...

[Page 27] LG 6CIM0-01B

3) Wrap the insulation material around the connecting portion. ① Overlap the connection pipe heat insulation and the indoor unit pipe heat insulation material. Bind them together with vinyl tape so that there may be no gap. ② Wrap the area which ...

[Page 28] LG 6CIM0-01B

10.6 Checking the Drainage 1) To check the drainage. ① Pour a glass of water on the evaporator. ② Ensure the water flows through the drain hose of the indoor unit without any leakage and goes out the drain exit. 2) Drain piping ① The drain hose...

[Page 29] LG 6CIM0-01B

ART COOL Mirror 1. List of functions 2. Specifications 3. Dimensions 4. Piping diagrams 5. Wiring Diagrams 6. Capacity Tables 7. Air flow and temperature distributions (reference data) 8. Sound levels 9. Controller 10. Installation Indoor unit ...

[Page 30] LG 6CIM0-01B

Note 1. * : These functions need to connect the wired remote controller. O : Applied X : Not applied Accessory model name : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate package. Category...

[Page 31] LG 6CIM0-01B

2. Specifications Note : 1. Wiring cable size must comply with the applicable local and national code. 2. Due to our policy of innovation some specifications may be changed without notification. 3. Sound Level Values are measured at Anechoic chamber....

[Page 32] LG 6CIM0-01B

3. Dimensions ART COOL Mirror _ 3 Indoor Units Indoor unit 76, Seongsan-dong, Changwon City, Gyeongnam, 641-713, Korea CHASSIS CODE: SB ART COOL Mirror AMNW09GDBR0[LMAN096HVT] AMNW12GDBR0[LMAN126HVT] Display & signal receiver Part Name Front pan...

[Page 33] LG 6CIM0-01B

76, Seongsan-dong, Changwon City, Gyeongnam, 641-713, Korea CHASSIS CODE: SC ART COOL Mirror AMNW18GDCR0[LMAN186HVT] Display & signal receiver Part Name Front panel Air suction grille Installation plate Knockout hole 5 No. 2 4 3 1 Remark Not...

[Page 34] LG 6CIM0-01B

4. Piping diagrams ART COOL Mirror _ 5 Indoor Units Indoor unit Gas pipe connection port (flare connection) Liquid pipe connection port (flare connection) Cooling Heating Thermistor for Evaporator Inlet Temperature Thermistor for Indoor Air Temper...

[Page 35] LG 6CIM0-01B

Models : AMNW09GDBR0 [LMAN096HVT] / AMNW12GDBR0 [LMAN126HVT] Models : AMNW18GDCR0 [LMAN186HVT] 5. Wiring diagrams 6 _ ART COOL Mirror Indoor Units Indoor unit ...

[Page 36] LG 6CIM0-01B

6. Capacity Tables ART COOL Mirror _ 7 Indoor Units Indoor unit n Cooling Capacity Notes: 1. Capacities are based on the following conditions. Corresponding refrigerant piping length : 25ft Level difference : 0ft 2. TC : Total Capacity(kBtu/h) SHC:...

[Page 37] LG 6CIM0-01B

Notes: 1. Capacities are based on the following conditions. Corresponding refrigerant piping length : 25ft Level difference : 0ft 2. TC : Total Capacity(kBtu/h) n Heating Capacity Heating capacity Unit Size (kBtu/h(kW)) Indoor air temp. °F DB Outdo...

[Page 38] LG 6CIM0-01B

7. Air flow and temperature distributions (reference data) ART COOL Mirror _ 9 Indoor Units Indoor unit Model : AMNW12GDBR0 [LMAN126HVT] Cooling Heating 72 68 75 64 Air velocity [ft/s] Temperature [F] 3.3 6.6 4.9 1.6 9ft 7ft 3ft 0ft 16ft 13ft 10ft 7...

[Page 39] LG 6CIM0-01B

7. Air flow and temperature distributions (reference data) 10 _ ART COOL Mirror Indoor Units Indoor unit Model : AMNW18GDCR0 [LMAN186HVT] Cooling Heating 3.3 6.6 4.9 1.6 Temperature [F] 91 86 81 75 70 Air velocity [ft/s] 9ft 7ft 3ft 0ft 26ft 23ft 20...

[Page 40] LG 6CIM0-01B

ART COOL Mirror _ 11 8. Sound levels Indoor Units Indoor unit 2.6ft 3.3ft Microphone Notes: - Sound measured at 3.3ft away from the center of the unit. - Data is valid at free field condition. - Data is valid at nominal operation condition. - Refere...

[Page 41] LG 6CIM0-01B

9. Controller Wireless remote control Display screen Control panel * Some functions may not be supported, depending on the model. Control panel Display screen Description a F Plasma button*:Plasmaster filter purifies the air by removing mites, mi...

[Page 42] LG 6CIM0-01B

10. Installation ART COOL Mirror _ 13 Indoor Units Indoor unit Name Installation panel Securing screws Type "A" screw Type "B" screw M4 x 12L (Other) • Owner's manual • Installation manual Diagram SB Chassis SC Chassis ...

[Page 43] LG 6CIM0-01B

Type 1: SB Chassis 133(5 1/4) 95(3 3/4) Installation plate Left rear piping Right rear piping Ø70(Ø2 3/4) Ø70(Ø2 3/4) Unit : mm(inch) 2) Installation plate dimensions Indoor Units 14 _ ART COOL Mirror 10. Installation Indoor unit ...

[Page 44] LG 6CIM0-01B

Type 2: SC Chassis Ø70(Ø2-3/4) Ø70(Ø2-3/4) 69(2 23/32) 56(2 7/32) Right rear piping Left rear piping Installation Plate Measuring Tape Measuring Tape Hanger Place a level on raised tab Unit Outline 207(8 5/32) 105(4 1/8) Unit : mm(inch) 460(18 ...

[Page 45] LG 6CIM0-01B

10. Installation 16 _ ART COOL Mirror Indoor Units Indoor unit 10.2 Selection of the best location ① There should not be any heat or steam near the unit. ② Select a place where there are no obstacles around of the unit. ③ Make sure that condens...

[Page 46] LG 6CIM0-01B

Wrong method • Following bending type from left to right may cause dam- age to the tubing. 10.5 Connecting the piping ① Pull the screw cap at the bottom of the indoor unit ② Remove the chassis cover from the unit by loosing 2 screws ③ Pull ba...

[Page 47] LG 6CIM0-01B

Indoor unit tubing Flare nut Pipings If the drain hose is routed inside the room insulate the hose with an insulation material* so that dripping from sweating (condensation) will not damage furniture or floors. CAUTION <Right side piping> �...

[Page 48] LG 6CIM0-01B

3) Wrap the insulation material around the connecting portion. ① Overlap the connection pipe heat insulation and the indoor unit pipe heat insulation material. Bind them together with vinyl tape so that there may be no gap. ② Wrap the area which ...

[Page 49] LG 6CIM0-01B

10.6 Checking the Drainage 1) To check the drainage. ① Pour a glass of water on the evaporator. ② Ensure the water flows through the drain hose of the indoor unit without any leakage and goes out the drain exit. 2) Drain piping ① The drain hose...

[Page 50] LG 6CIM0-01B

Ceiling cassette 4-way 1. List of functions 2. Specifications 3. Dimensions 4. Piping diagrams 5. Wiring Diagrams 6. Capacity Tables 7. Air flow and temperature distributions (reference data) 8. Sound levels 9. Controller 10. Installation Indoor uni...

[Page 51] LG 6CIM0-01B

Indoor Units 1. List of functions Ceiling cassette 4-way _ 1 Indoor unit Air supply outlet 4 Airflow direction control (left & right) X Airflow direction control (up & down) Auto Auto swing (left & right) X Air flow Auto swing (up & d...

[Page 52] LG 6CIM0-01B

2. Specifications 2 _ Ceiling cassette 4-way Indoor Units Indoor unit Note : 1. Wiring cable size must comply with the applicable local and national code. 2. Due to our policy of innovation some specifications may be changed without notification. 3. ...

[Page 53] LG 6CIM0-01B

Ceiling cassette 4-way _ 3 3. Dimensions Indoor Units Indoor unit 76, Seongsan-dong, Changwon City, Gyeongnam, 641-713, Korea CHASSIS CODE: TR Drain pipe connection Air suction grille Part Name Decoration panel Air discharge grille Liquid pipe co...

[Page 54] LG 6CIM0-01B

3. Dimensions 4 _ Ceiling cassette 4-way Indoor Units Indoor unit 76, Seongsan-dong, Changwon City, Gyeongnam, 641-713, Korea CHASSIS CODE: TQ Drain pipe connection Air suction grille Part Name Decoration panel Air discharge grille Liquid pipe conn...

[Page 55] LG 6CIM0-01B

Ceiling cassette 4-way _ 5 4. Piping diagrams Indoor Units Indoor unit Heat exchanger Gas pipe connection port (flare connection) Liquid pipe connection port (flare connection) Turbo fan Cooling Heating M Thermistor for Evaporator Inlet Temperatur...

[Page 56] LG 6CIM0-01B

5. Wiring diagrams 6 _ Ceiling cassette 4-way Indoor Units Indoor unit Models: AMNW12GTRA0[LMCN125HV] / AMNW18GTQA0[LMCN185HV] ...

[Page 57] LG 6CIM0-01B

Ceiling cassette 4-way _ 7 6. Capacity Tables Indoor Units Indoor unit n Cooling Capacity Notes: 1. Capacities are based on the following conditions. Corresponding refrigerant piping length : 25ft Level difference : 0ft 2. TC : Total Capacity(kBtu/...

[Page 58] LG 6CIM0-01B

6. Capacity Tables 8 _ Ceiling cassette 4-way Indoor Units Indoor unit Notes: 1. Capacities are based on the following conditions. Corresponding refrigerant piping length : 25ft Level difference : 0ft 2. TC : Total Capacity(kBtu/h) n Heating Capacit...

[Page 59] LG 6CIM0-01B

Ceiling cassette 4-way _ 9 7. Air flow and temperature distributions (reference data) Indoor Units Indoor unit Model : AMNW18GTQA0[LMCN185HV] Cooling Heating 9ft 7ft 3ft 0ft 13ft10ft10ft 7ft7ft 3ft0ft3ft13ft 9ft 7ft 3ft 0ft 13ft10ft10ft 7ft7ft 3ft0f...

[Page 60] LG 6CIM0-01B

8. Sound levels 10 _ Ceiling cassette 4-way Indoor Units Indoor unit Notes: - Sound measured at 4.9ft away from the center of the unit. - Data is valid at free field condition. - Data is valid at nominal operation condition. - Reference accoustic pr...

[Page 61] LG 6CIM0-01B

Ceiling cassette 4-way _ 11 9. Controller Indoor Units Indoor unit Wired remote controller(PQWRHDF0) Cooling Mode Auto Operation Dehumidification mode Heating Mode Fan Mode • Cooling Model( ), Heat Pump Model( ) Operation Mode 13 14 15 16 1 8 9...

[Page 62] LG 6CIM0-01B

10. Installation 12 _ Ceiling cassette 4-way Indoor Units Indoor unit Name Quantity Shape for gas pipe Conduit Bracket Screw(M4) 2EA for liquid pipe Clamp metal 1 EA Insulation for fitting 1 SET Drain hose 1 EA Clamp Conduit Bracket 8 EA Washer fo...

[Page 63] LG 6CIM0-01B

Ceiling cassette 4-way _ 13 10. Installation Indoor Units Indoor unit 10.2 Selection of the best location • There should not be any heat source or steam near the unit. • There should not be any obstacles to the air circulation. • There should...

[Page 64] LG 6CIM0-01B

- Countermeasure: • Use the carpet on the floor (compared to the tiles the carpet over it will have a 3 degree rise in temperature) • Insulating the floor. • Floor heating 3) In case of high temperature or high humidity between the false ceilin...

[Page 65] LG 6CIM0-01B

10.4 Ceiling opening dimensions and hanging bolt location ① The dimensions of the paper pattern for installation are the same as those of the ceiling opening dimensions. ② Select and mark the position for fixing bolts and piping hole. ③ Decide ...

[Page 66] LG 6CIM0-01B

10. Installation 16 _ Ceiling cassette 4-way Indoor Units Indoor unit • The following parts are local purchasing. - Hanging Bolt - W 3/8 or M10 - Nut - W 3/8 or M10 - Spring Washer - M10 - Plate Washer - M10 2) For new ceilin...

[Page 67] LG 6CIM0-01B

Ceiling cassette 4-way _ 17 10. Installation Indoor Units Indoor unit • Be sure to install heat insulation on the drain piping. 4) Drain test 10.7 Installation of decoration panel Heat insulation material: Polyethylene foam with thick- ness more th...

[Page 68] LG 6CIM0-01B

10. Installation 18 _ Ceiling cassette 4-way Indoor Units Indoor unit 3. Fit the panel on the unit by inserting hooks as shown in picture. 4. Insert two screws on diagonal corners of panel. Do not tighten the bolts completely. (The fixing screws are ...

[Page 69] LG 6CIM0-01B

Ceiling cassette 4-way _ 19 10. Installation Indoor Units Indoor unit 10.8 Electric wiring work 1) General instructions ① All field supplied parts and materials, electric works must conform to local codes. Use copper wire only. ② Follow the &qu...

[Page 70] LG 6CIM0-01B

10. Installation 20 _ Ceiling cassette 4-way Indoor Units Indoor unit 1. Use round crimp-style terminals for connecting wires to the power supply terminal block. If unavailable, observe the following points when wiring. • Do not connect wires of d...

[Page 71] LG 6CIM0-01B

Ceiling concealed duct - Low static pressure 1. List of functions 2. Specifications 3. Dimensions 4. Piping diagrams 5. Wiring Diagrams 6. Capacity Tables 7. External pressure setting 8. Sound levels 9. Controller 10. Installation Indoor unit ...

[Page 72] LG 6CIM0-01B

Ceiling concealed duct - low static pressure _ 1 1. List of functions Indoor Units Indoor unit Air supply outlet 1 Airflow direction control (left & right) X Airflow direction control (up & down) X Auto swing (left & right) X Air flow Aut...

[Page 73] LG 6CIM0-01B

2. Specifications 2 _ Ceiling concealed duct - low static pressure Indoor Units Indoor unit Note : 1. Wiring cable size must comply with the applicable local and national code. 2. Due to our policy of innovation some specifications may be changed wit...

[Page 74] LG 6CIM0-01B

Ceiling concealed duct - low static pressure _ 3 3. Dimensions Indoor Units Indoor unit 76, Seongsan-dong, Changwon City, Gyeongnam, 641-713, Korea CHASSIS CODE: B1 CEILING CONCEALED DUCT AMNW09GB1A0[LMDN095HV] AMNW12GB1A0[LMDN125HV] Air discharge f...

[Page 75] LG 6CIM0-01B

3. Dimensions 4 _ Ceiling concealed duct - low static pressure Indoor Units Indoor unit 76, Seongsan-dong, Changwon City, Gyeongnam, 641-713, Korea CHASSIS CODE: B2 CEILING CONCEALED DUCT AMNW18GB2A0[LMDN185HV] Air discharge flange Part Name Air suc...

[Page 76] LG 6CIM0-01B

Ceiling concealed duct - low static pressure _ 5 4. Piping diagrams Indoor Units Indoor unit Heat exchanger Gas pipe connection port (flare connection) Liquid pipe connection port (flare connection) Cooling Heating Thermistor for Evaporator Inlet T...

[Page 77] LG 6CIM0-01B

4. Piping diagrams 6 _ Ceiling concealed duct - low static pressure Indoor Units Indoor unit Heat exchanger Gas pipe connection port (flare connection) Liquid pipe connection port (flare connection) Cooling Heating Thermistor for Evaporator Inlet T...

[Page 78] LG 6CIM0-01B

Ceiling concealed duct - low static pressure _ 7 5. Wiring diagrams Indoor Units Indoor unit Models: AMNW09GB1A0[LMDN095HV] / AMNW12GB1A0[LMDN125HV] AMNW18GB2A0[LMDN185HV] ...

[Page 79] LG 6CIM0-01B

6. Capacity Tables 8 _ Ceiling concealed duct - low static pressure Indoor Units Indoor unit n Cooling Capacity Notes: 1. Capacities are based on the following conditions. Corresponding refrigerant piping length : 25ft Level difference : 0ft 2. TC ...

[Page 80] LG 6CIM0-01B

Ceiling concealed duct - low static pressure _ 9 6. Capacity Tables Indoor Units Indoor unit Notes: 1. Capacities are based on the following conditions. Corresponding refrigerant piping length : 25ft Level difference : 0ft 2. TC : Total Capacity(kBt...

[Page 81] LG 6CIM0-01B

7. External pressure setting 10 _ Ceiling concealed duct - low static pressure Indoor Units Indoor unit E.S.P. Control provide required constant air flow rate irrespective of E.S.P. charge. <Installer Setting Code Table> 1) General air-conditio...

[Page 82] LG 6CIM0-01B

Ceiling concealed duct - low static pressure _ 11 7. External pressure setting Indoor Units Indoor unit How to Set E.S.P. on the remote controller? • If you set ESP incorrectly, the air conditioner may malfunction. • This setting must be carried...

[Page 83] LG 6CIM0-01B

7. External pressure setting 12 _ Ceiling concealed duct - low static pressure Indoor Units Indoor unit [ Notes ] 1. To get the desired Airflow & E.S.P. combination from the table set the matching value from the table. Value other than that in t...

[Page 84] LG 6CIM0-01B

Ceiling concealed duct - low static pressure _ 13 8. Sound levels Indoor Units Indoor unit Notes: - Data is valid at nominal operation condition - Reference accoustic pressure OdB = 20Pa - Sound level will vary depending on a range of factors such ...

[Page 85] LG 6CIM0-01B

9. Controller 14 _ Ceiling concealed duct - low static pressure Indoor Units Indoor unit 1) Wired remote controller 2 3 4 5 TEMP FAN SPEED OPER MODE 1 1. Operation Display Panel 2. Temperature Control Button 3. Fan Speed Button 4. On/Off Button 5. ...

[Page 86] LG 6CIM0-01B

Ceiling concealed duct - low static pressure _ 15 9. Controller Indoor Units Indoor unit 2) Wide wired remote controller(accessory) 1 4 5 7 11 10 9 8 2 3 6 13 12 Please attach the inform label inside of the door. Please choose proper language depend...

[Page 87] LG 6CIM0-01B

10. Installation 16 _ Ceiling concealed duct - low static pressure Indoor Units Indoor unit • Please read the instruction sheets completely before installing the product. • When the power cord is damaged, replacement work shall be performed by au...

[Page 88] LG 6CIM0-01B

Ceiling concealed duct - low static pressure _ 17 10. Installation Indoor Units Indoor unit 10.2 Selection of the best location Install the air conditioner in the location that satisfies the fol- lowing conditions. • The place shall easily bear a l...

[Page 89] LG 6CIM0-01B

10. Installation 18 _ Ceiling concealed duct - low static pressure Indoor Units Indoor unit • Tighten the nut and bolt to prevent the unit falling. CAUTION 3) Install a canvass duct to the air discharge outlet and air inlet so that vibration from...

[Page 90] LG 6CIM0-01B

Ceiling concealed duct - low static pressure _ 19 10. Installation Indoor Units Indoor unit ⑥ Insert the set anchor and washer onto the suspension bolts for locking the suspension bolts on the ceiling. ⑦ Mount the suspension bolts to the set anch...

[Page 91] LG 6CIM0-01B

3) Indoor unit drain piping ① Drain piping must have down-slope (1/50 to 1/100): be sure not to provide up-and-down slope to prevent rever- sal flow. ② During drain piping connection, be careful not to exert extra force on the drain port on the i...

[Page 92] LG 6CIM0-01B

Ceiling concealed duct - low static pressure _ 21 10. Installation Indoor Units Indoor unit - With drain pump ① Possible drain head height is upto 27 6/19 inch. So the drain head should be below 27 6/19 inch. ② Keep the drain hose downward upto 1...

[Page 93] LG 6CIM0-01B

Clamping of cables ① Arrange 2 power cables on the control panel. ② First, fasten the steel clamp with a screw to the inner boss of control panel. ③ For the cooling model, fix the other side of the clamp with a screw strongly. For the heat pump...

[Page 94] LG 6CIM0-01B

P/No.: MFL67502502 Air Conditioner 20 Yeouido-dong, Yeongdeungpo-gu, Yeouido P.O.Box 335 Seoul, 150-721, Korea. http://www.lgeaircon.com All rights reserved December / 2012Printed in Korea The specifications, designs, and information in this brochu...